Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 1700   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 24  |  Issue : 5  |  Page : 660-666

Evaluating the effect of subcrestal placement on platform switched short dental implants and von mises stress in D3 bone–A 3D FEM study


1 Department of Periodontics, College of Dentistry, Gulf Medical University, Ajman, UAE
2 Department of Periodontics, Rajah Muthiah Dental College and Hospital, Annamalai, Chidambaram, Tamil Nadu, India

Correspondence Address:
Dr. M S Reddy
Lecturer, Department of Periodontics, College of Dentistry, Gulf Medical University, Ajman, 4184
UAE
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_362_20

Rights and Permissions

Aim: To investigate the effect of platform switched short dental implants and subcrestal placement on von Mises stress in the maxillary anterior region (D3 bone) by using three-dimensional finite element model analyses (3D FEM). Materials and Methods: Biomechanical behaviour of von Mises stress in maxillary anterior region (D3) bone were stimulated with the help of 3D FEM with the help of ANSYS WORKBENCH version 17.5. The bone model had a cortical core of (1 mm) surrounding the inner cancellous core, which represents D3 bone. Two models were designed model 1 (6 x 4.6 mm), (7.5 x 4.6 mm) and model 2 (6 x 5.8 mm), (7.5 x 5.8 mm). Loads of 100, 200 N were applied at an angle of 0°, 15°, 30° along the long axis of the tooth model. Results: In all model's cortical bone exhibited greater stress than cancellous bone. Greater stress was reported in axial direction at 30° then 15° and least at 0° irrespective of load applied. An increase in implant length (7.5 mm) did not exhibit any stress reduction in both the model but implant diameter (5.8 mm) led to reduction in von Mises stress in both the groups. Greater the force applied greater was stress in both bones irrespective of direction of force applied (200N). Lastly subcrestal (0.5 mm) placement has slight reduction in stress compared to equicrestal placement in both the groups. Conclusion: Numerical results from the current study suggest that, for short implants, implant diameter is considered more effective design parameter than implant length. Current findings state that platform switch short subcrestal implants results in conservation of marginal bone loss along with better stress distribution around peri-implant regions in D3 bone. However, all models analyzed in this study showed development of von Mesies stresses within physiological limits for human cortical bone.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed756    
    Printed8    
    Emailed0    
    PDF Downloaded99    
    Comments [Add]    

Recommend this journal