Pull-out bond strength of fiber post luted with two types of resin luting cements using different light curing units


1 Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
2 AlSha'alaniyah Primary Care Center, Ministry of Health, Hail, Saudi Arabia
3 AlNusbah Primary Care Center, Ministry of Health, Tabuk, Saudi Arabia
4 Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

Correspondence Address:
Dr. S Ali
Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_32_21

Rights and Permissions

Aims: The aim of this study was to evaluate the pull-out bond strength of fiber post when cemented with a self-adhesive dual-cured resin luting cement and a conventional light-cured resin luting cement. In addition, the influence of a light-emitting diode (LED) and halogen (QTH) curing lights on the pull-out bond strength was assessed. Materials and Methods: A total of 40 extracted human teeth were selected. Post-space preparation of 10 mm was done and two types of resin cement i.e. RelyX Unicem (RXU) and variolink esthetic LC (VLE) were used for cementation of a translucent RelyX fiber post. Light activation for 60 s was done with LED and QTH curing units. The pull-out test was performed parallel to the long axis of the tooth and the post at a crosshead speed of 1 mm/min using a universal testing machine. The load required to dislodge each post was recorded in Newton (N). Statistical analysis was done and a value of P < 0.05 was considered statistically significant. Results: The RXU showed a mean (SD) pull-out bond strength of 203.5N (47.1) and 207.3N (31.3) when light activated with LED and QTH curing lights, respectively. For VLE, the mean pull-out bond strength was 78.9N (21.5) and 87.7N (30.7), when light activated with LED and QTH curing lights, respectively. Moreover, LED and QTH curing lights did not influence the pull-out bond strength for both the test materials. Conclusion: It is concluded that a dual-cured resin luting cement should be used for the cementation of fiber post. Further research is required to understand the light transmission of translucent fiber posts.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1294    
    Printed32    
    Emailed0    
    PDF Downloaded208    
    Comments [Add]    

Recommend this journal